-
Calibre de pressão diferencial
-
calibre de pressão digital
-
Calibre de pressão de aço inoxidável
-
Transmissor de pressão da precisão
-
Controlador programável da lógica
-
Interruptor nivelado do flutuador
-
Positioner da válvula pneumática
-
Sensor do transmissor da temperatura
-
Hart Field Communicator
-
Válvula de solenoide
-
Válvulas de controle
-
Medidor de fluxo da precisão alta
-
bomba de água submergível
-
Distribuidor do transmissor de pressão
-
Medidor nivelado ultrassônico
-
Medidor de poder atual da tensão
Honeywell TBC2800A1000 Combustion Safety Programmer New Condition for Manufacturing Plants and Restaurants

Contacte-me para amostras grátis e vales.
whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
Se você tem algum interesse, nós fornecemos a ajuda online de 24 horas.
xmachinery test report | Provided | Material | plastic |
---|---|---|---|
Weight (kg) | 1 | warranty | 1 years |
FEATURES • Compatible to UV, Double rod (separated flame rod and igni-tion rod) and 1 rod (integrated flame rod and ignition rod) flame detection which can be set manually • Integrate 6 kinds of timing choices which can be set manually according to the application requirements • 24 hours continuous operation (except UV application) • Life-cycle ≥ 250K times (Note 1) • IP54 protection field or cabinet installation • Multifunctional LED lights and buttons indicate the Flame strength, fault & operation sequence and parameters • Remote or on-site reset • Adjustable flame on-off threshold • Comply with EN298 SPECIFICATIONS W x D x H: 122.5 x 82 x 131.2mm Mains input 220/230VAC –15/+10% 50 60Hz Power consumption 9 VA Cable length of flame rod: 75m(max) Cable length of UV 75m max) Flame threshold setting 1~10µA Cover material PC/ABS Protection class IP54 Ambient temperature -20 +60 Ambient humidity 95%, non condensing Lifecycle 250,000 cycles comply with EN298 Drive gas valve 1A(max) power factor 1 Drive ignition transformer 2A(max) PF 0.2 Maximum output for terminal 2A 242Vac UV sensor C7027A/C7035A/C7044A CAUTION • Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. • Check the ratings given in the instructions and marked on the product to make sure the product is suitable for the application. • Installer must be a trained, experienced, flame safeguard ser-vice technician. • After installation is completed, the operation parameters should be set by the authorized person according to the application requirements and this product handbook. • Keep the flame detector cable and ignition cable as far as possible. • C7027A/C7035A/C7044A is not the self-checking UV sensor, so TBC2800 should be restarted once every 24 hours. Note1: If one rod flame detection is applied, TBC2800 lifecycle will be 100,000 times.